Genicular nerve radiofrequency ablation

Form ID: genicular_rfa   Type: Procedure   Family: Radiofrequency ablation

Structured fields

SectionFieldKeyDefault layerRequiredQuick text templatesHistory/exam sources
SafetyConsent discussionconsent_phraseGlobal DefaultRequiredReviewed today and no patient-specific contraindication identified.; Patient-specific exception documented in the free-text field.
SafetyTime-out and safety screentimeout_phraseGlobal DefaultRequiredReviewed today and no patient-specific contraindication identified.; Patient-specific exception documented in the free-text field.
SafetyAllergy / infection / anticoagulant screen resultallergy_infection_anticoagulant_screenNo DefaultRequiredNo known relevant allergies; no active infection symptoms; anticoagulant/antiplatelet status reviewed.; Medication/allergy list reviewed; no contraindication identified today.; Anticoagulant/antiplatelet plan reviewed and documented before proceeding.; Reviewed today and no patient-specific contraindication identified.; Patient-specific exception documented in the free-text field.red_flags_neuro_screen; red_flag_exam_findings; current_medications
IndicationDiagnosis / indicationdiagnosisNo DefaultRequiredcondition_focus; pain_generator_impression; history_impression_plan
IndicationClinical indication and failed conservative therapyclinical_indicationNo DefaultRequiredPersistent function-limiting pain despite conservative management; procedure offered for diagnostic and/or therapeutic benefit.; Symptoms, examination, and available imaging are concordant with the planned target.; Prior treatment response and patient goals reviewed; patient wishes to proceed.presenting_complaint; pain_location_distribution; functional_limitations; prior_treatments; imaging_labs_tests; pain_generator_impression; procedural_target_assessment
IndicationLaterality / sidesideNo DefaultRequired
SetupPatient positionpatient_positionPer-Form DefaultRequired
SetupSkin preparationskin_prepGlobal DefaultRequired
SetupSterile setupsterile_setupGlobal DefaultRequired
SetupMonitoringmonitoringGlobal DefaultRequired
GuidanceGuidance modalityguidancePer-Form DefaultRequired
GuidanceGuidance documentation phraseguidance_phraseGlobal DefaultRequired
GuidanceImages saved / archive locationimage_savedNo DefaultRequiredRepresentative images saved to clinic imaging archive.; Image storage not technically feasible; guidance findings documented in note.; Fluoroscopic images stored according to clinic workflow.imaging_labs_tests; procedural_target_assessment
OutcomeImmediate response / pain score changeimmediate_responseNo DefaultRequiredTolerated well; immediate response to be assessed over the expected therapeutic window.; No immediate complication; post-procedure pain/function response reviewed before discharge.; Immediate pain score and functional response documented after reassessment.; No immediate complication observed.; Response will be reassessed after the expected onset window.history_impression_plan; exam_plan
OutcomeComplications / adverse eventcomplicationsNo DefaultRequiredNone.; No immediate adverse event observed.; Transient expected procedural discomfort only.; No immediate complication observed.; Response will be reassessed after the expected onset window.
DispositionPost-procedure instructionspost_procedure_instructionsGlobal DefaultRequiredPost-procedure instructions and warning signs reviewed; patient advised to seek urgent care for concerning symptoms.; Activity modification, expected soreness, medication precautions, and red flags reviewed.; Written and verbal aftercare instructions provided according to clinic protocol.; Aftercare, red flags, and follow-up plan reviewed with patient.
DispositionFollow-up planfollow_up_planGlobal DefaultRequiredFollow-up arranged according to response and treatment plan; patient advised to track pain, function, and adverse effects.; Reassess pain score, functional change, medication use, and adverse effects at follow-up.; Patient will contact clinic earlier for concerning symptoms or inadequate response.; Aftercare, red flags, and follow-up plan reviewed with patient.history_impression_plan; exam_plan; patient_preferences_affordability
TargetsLevels / nerves targetedlevels_targetsNo DefaultRequired
TechniqueImaging modalityimaging_modalityPer-Form DefaultRequired
TechniqueRF cannula / active tipcannulaPer-Form DefaultRequired
TechniqueRF generator / technologygeneratorPer-Form DefaultRequired
TechniqueElectrode orientation / lesion geometryelectrode_orientationPer-Form DefaultRequired
StimulationSensory stimulation resultsensory_stimulationNo DefaultRequired
StimulationMotor stimulation resultmotor_stimulationNo DefaultRequired
LesioningLesion temperature/time/settingslesion_settingsPer-Form DefaultRequired
LesioningNumber of lesionsnumber_of_lesionsNo DefaultRequired
LesioningPost-lesion injectatepost_lesion_injectatePer-Form DefaultOptional
OutcomePost-procedure neurologic statuspost_procedure_neuro_statusNo DefaultRequiredNo immediate complication observed.; Response will be reassessed after the expected onset window.
TargetsDiagnostic block response supporting RFAdiagnostic_block_responseNo DefaultRequired
SafetyAnticoagulant/antiplatelet plananticoagulant_hold_detailsNo DefaultOptionalReviewed today and no patient-specific contraindication identified.; Patient-specific exception documented in the free-text field.
Recommended next procedureRecommended next procedure datenext_procedure_dateNo DefaultRequired
Recommended next procedureMedication choicenext_procedure_medication_choicePer-Form DefaultRequired
Recommended next procedureDosenext_procedure_dosePer-Form DefaultRequired
Recommended next procedureTechniquenext_procedure_techniquePer-Form DefaultRequired
Recommended next procedurePatient positionnext_procedure_patient_positionPer-Form DefaultRequired
Recommended next procedurePremedicationnext_procedure_premedicationPer-Form DefaultOptional
Recommended next procedurePre-procedure commentsnext_procedure_pre_procedure_commentsPer-Form DefaultOptionalReassess indication, response to current procedure, contraindications, patient preference, and affordability before proceeding.; Repeat only if clinically indicated after response and safety review.; Confirm medication/product availability, consent, and interval safety before booking.history_impression_plan; exam_plan; patient_preferences_affordability
Recommended next procedureIntra-procedure commentsnext_procedure_intra_procedure_commentsPer-Form DefaultOptionalUse same technique unless anatomy, response, or safety considerations require modification.; Adjust target/approach based on updated exam, imaging, and response to previous procedure.; Document any change in guidance, target, needle/cannula, or device settings.
Recommended next procedurePost-procedure commentsnext_procedure_post_procedure_commentsPer-Form DefaultOptionalReassess response, adverse effects, function, and need for further treatment after the next procedure.; Track pain diary, functional goals, and medication change after the next procedure.; Review whether further repeat procedure remains appropriate before additional treatment.

Narrative template

Genicular Nerve Radiofrequency Ablation

Indication: {{side}} genicular RFA for {{diagnosis}}. Diagnostic block response: {{diagnostic_block_response}}. {{clinical_indication}}

Consent / safety: {{consent_phrase}} {{timeout_phrase}} Safety screen: {{allergy_infection_anticoagulant_screen}}

Setup/guidance: Position: {{patient_position}}. Monitoring: {{monitoring}}. Guidance: {{imaging_modality}}. Images: {{image_saved}}

Targets: {{levels_targets}}. Cannula: {{cannula}}. Generator: {{generator}}. Orientation: {{electrode_orientation}}

Stimulation/lesioning: Sensory stimulation: {{sensory_stimulation}} Motor stimulation: {{motor_stimulation}} Settings: {{lesion_settings}} Number of lesions: {{number_of_lesions}}. Post-lesion injectate: {{post_lesion_injectate}}

Outcome: Neuro status: {{post_procedure_neuro_status}}. Immediate response: {{immediate_response}} Complications: {{complications}}

Disposition: {{post_procedure_instructions}} {{follow_up_plan}}

Recommended next procedure: Date: {{next_procedure_date}}. Medication choice: {{next_procedure_medication_choice}}. Dose: {{next_procedure_dose}}. Technique: {{next_procedure_technique}}. Patient position: {{next_procedure_patient_position}}. Premedication: {{next_procedure_premedication}}. Pre-procedure comments: {{next_procedure_pre_procedure_comments}}. Intra-procedure comments: {{next_procedure_intra_procedure_comments}}. Post-procedure comments: {{next_procedure_post_procedure_comments}}.

Physician review required before signing in the EMR. Verify actual medications, doses, lot/expiry, devices, image documentation, response, complications, and follow-up.